2013 American journal of dentistry

Adhesion to primary dentin: microshear bond strength and scanning electron microscopic observation.

, , , ,

American journal of dentistry Vol. 26 (6) : 341-6 • Dec 2013

PURPOSE: To compare the bond strength to human primary dentin of a self-adhesive light-curing resin composite, a self-etch adhesive and a glass-ionomer cement by means of microshear bond strength (pSBS) test and scanning electron microscopic (SEM) observations. METHODS: 75 human primary molars were sectioned to obtain a 2 mm-thick slab of mid-coronal dentin, randomly divided into three groups (n=25). Nine conical frustum-shaped buildups were constructed on the occlusal surface of each dentin slab using a self-adhesive light-curing resin composite (Vertise Flow; Group 1), bonding agent (Optibond All-in-One; Group 2) combined with resin composite (Premise Flow) and a glass-ionomer cement (Ketac-Fil; Group 3). After thermocycling, specimens were subjected to microSBS test. All debonded specimens were observed at SEM. Data were analyzed by a mixed model and chi-square test. RESULTS: The bond strength measured in Group 1 (9.0 +/- 4.5 MPa) was significantly lower than that one recorded in Group 2 (20.2 +/-12.5 MPa) although it was significantly higher than the one recorded in Group 3 (4.8 +/- 2.3 MPa). Failures were mainly adhesive in all groups.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
+5 more
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.