2014 The European journal of prost…

Dimensional stability ofautoclave sterilised addition cured impressions and trays.

, ,

The European journal of prosthodontics and restorative dentistry Vol. 22 (1) : 35-42 • Mar 2014

The aim of this study was to investigate the dimensional accuracy of impressions following sterilisation by autoclaving. Dental impressions (75) were of a dentoform containing 6 reference points. The impressions were split into 5 groups of 15, each group used a different impression technique. Groups were divided into 3 subgroups with 5 impressions as control, 5 for disinfection by Perform-ID and 5 being autoclaved. Measurements were made using a travelling light microscope. A minimal significant dimensional difference (0.01<P<0.05) was observed when using the one-stage impression method. No significant dimensional differences were observed for all other groups (P>0.05). The trays and materials tested were suitable for the autoclave sterilisation.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.