STATEMENT OF PROBLEM: Selective laser melting (SLM) technology has been introduced to fabricate dental restorations. However, the fit of these restorations still needs further study. PURPOSE: The purpose of this in vivo investigation was to compare the marginal and internal fit of SLM metal ceramic crowns with 2 lost-wax cast metal ceramic crowns and to evaluate the influence of tooth type on the marginal and internal fit of these crowns. MATERIAL AND METHODS: A total of 330 metal ceramic crowns were evaluated. The metal copings were fabricated with SLM Co-Cr, cast Au-Pt, and cast Co-Cr alloy (n=110). The marginal and internal gaps of crowns were recorded by using a replica technique. The anterior and premolar replicas were sectioned 2 times, and molar replicas were sectioned 4 times. The marginal and internal gap width of each cross section was examined by stereomicroscope at x30 magnification. Two-way analysis of variance was performed to identify the statistical difference among the groups. RESULTS: The marginal fit of the SLM Co-Cr group (75.6 +/-32.6 mum) was not different from the cast Au-Pt group (76.8 +/-32.1 mum) (P>.05) but was better than the cast Co-Cr group (91.0 +/-36.3 mum) (P<.01). No significant difference was found among the SLM Co-Cr group (127.3 +/-45.8 mum), cast Au-Pt group (129.9 +/-61.1 mum). and cast Co-Cr group (142.5 +/-63.7 mum) (P>.05). The mean occlusal gap width of the SLM Co-Cr group (309.8 +/-106.6 mum) was significantly higher than that of the cast Au-Pt group (254.6 +/-109.6 mum) and the cast Co-Cr group (249.6 +/-110.4 mum) (P<.005). No significant difference was found in the marginal fit among the anterior group (84.4 +/-35.1 mum), the premolar group (80.6 +/-26.3 mum), and the molar group (82.7 +/-38.0 mum) (P>.05). Also, no significant difference was found in the axial fit among the anterior group (138.3 +/-52.5 mum), the premolar group (132.9 +/-50.4 mum), and the molar group (134.4 +/-52.5 mum) (P>.05). The anterior group (267.6 +/-110.2 mum) did not differ from the premolar group (270.2 +/-112.8 mum) and the molar group (268.6 +/-110.5 mum) in occlusal fit (P>.05). CONCLUSIONS: The marginal fit of SLM Co-Cr metal ceramic crowns was similar to that of the cast Au-Pt metal ceramic crowns and was better than that of the cast Co-Cr metal ceramic crowns. The SLM Co-Cr metal ceramic crowns were not significantly different from the 2 cast metal ceramic crowns in axial fit but were less accurate in occlusal fit. Tooth type did not influence the marginal and internal fit of the metal ceramic crowns.
No clinical trial protocols linked to this paper
Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.PICO Elements
No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.
Paper Details
MeSH Terms
Associated Data
No associated datasets or code repositories found for this paper.
Related Papers
Related paper suggestions will be available in future updates.