STATEMENT OF PROBLEM: Partial fixed dental prostheses with a small connector size are required for optimal esthetics and limited interarch space; however, final strength is endangered. PURPOSE: The purpose of this in vitro study was to evaluate the effect of different connector designs on the flexural strength of simulated 3-unit partial fixed dental prostheses made of yttria-stabilized tetragonal zirconia polycrystalline using computer-aided design and computer-aided manufacturing technology. MATERIAL AND METHODS: To simulate a 3-unit partial fixed dental prosthesis, 20 rectangular bar-shaped specimens were fabricated with dimensions of 4 +/- 0.05 mm (H) x 4 +/- 0.05 mm (W) x 30 0.5 mm (L). Each bar specimen had 2 constricted parts on both sides, representing the connector and defining a central pontic of 10 +/- 0.10 mm in length. The specimens were divided into 4 groups according to the connector diameter and design, as follows: SR: 2 mm (H) x 3 mm (W) round 0.6 mm radius of curvature; SS: 2 mm (H) x 3 mm (W) sharp 0.1 mm radius of curvature; CR: 3 mm (H) x 3 mm (W) round 0.6 mm radius of curvature; and CS: 3 mm (H) x 3 mm (W) sharp 0.1 mm radius of curvature. An additional 5 specimens were fabricated with no constriction and served as the control group. The specimens were subjected to a 3-point flexural strength test in a universal testing machine with a crosshead speed of 0.5 mm/min until failure. Scanning electron microscopic and photomicrograph images were used to examine the fracture surfaces. Two-way ANOVA and the Tukey-Kramer post hoc test were used to analyze the data (alpha = .05). RESULTS: The mean flexural strength for SR 2 mm (H) x 3 mm (W) round 0.6 mm radius of curvature (583.6 +/- 49.7 MPa) was significantly higher than that of SS, which was 2 mm (H)x 3 mm (W) sharp 0.1 mm radius of curvature (502.8 +/- 23.3 MPa). Similarly, the mean flexural strength for CR was 3 mm (H) x 3 mm (W) round 0.6 mm radius of curvature (682.9 +/- 36.8), which was significantly higher than that of CC, 3 mm (H) x 3 mm (W) sharp 0.1 mm radius of curvature (486.7 +/- 35.6 MPa). CONCLUSIONS: The flexural strength of the yttria-stabilized tetragonal zirconia polycrystalline-based ceramics was affected by the connector dimension and design. The 2-round connector design was more able to withstand occlusal forces than the sharp design. The 3-connector design with a minimum cross section of 2 x 3 mm is recommended for anterior fixed dental prostheses, provided it has a round curvature.
No clinical trial protocols linked to this paper
Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.PICO Elements
No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.
Paper Details
MeSH Terms
Associated Data
No associated datasets or code repositories found for this paper.
Related Papers
Related paper suggestions will be available in future updates.