[Influence of different acid etching modes on bond strengths to non-carious sclerotic dentin].
PURPOSE: To evaluate the effect of different acid etching modes on bond strength between composite resin and non-carious sclerotic dentin, and to provide references for clinical application. MOTHODS: Thirty premolars with naturally-occurring non-carious cervical lesions were divided into 2 groups based on self-etch adhesive system AdperTM Easy one (AEO) and total-etch adhesive system AdperTM Single Bond2 (ASB2). Each group was further divided into 3 subgroups (ASB21, ASB22, ASB23, AEO1, AEO2, AEO3) and subjected to the following processing: ASB21 subgroup was etched for 15 s with 35% phosphoric acid and coated with binder for 15 s; ASB22 subgroup was etched for 30 s with 35% phosphoric acid and coated with binder for 15 s; ASB23 subgroup was etched for 15 s with 35% phosphoric acid and coated with binder for 30 s; AEO1 subgroup was only etched with binder for 20 s; AEO2 subgroup was etched with binder for 40 s; AEO3 subgroup was etched for 15 s with 35% phosphoric acid and coated with binder for 20 s. The samples were restored with composite resin; 24 h after saved in distilled water at room temperature, the teeth were cut into dumbbell-shaped specimens with surface areas of approximately 1.0 mm2. The microtensile bond strength (muTBS) was detected and evaluated by one-way ANOVA and SNK-q test using SPSS 17.0 software package. RESULTS: muTBS was given in MPa: AEO3>ASB22>ASB23>ASB21>AEO2>AEO1, AEO3 resulted in statistically highest bond strength and AEO1 had the lowest bond strength (P<0.05), ASB22 acquired bond strength just lower than AEO3 (P<0.05). CONCLUSIONS: Use of total-etch adhesive system increasing the etching time of phosphoric time can enhance bond strength. For self-etch adhesive system,both duplicated the time of adhesive treatment and use of phosphoric acid can improve the bond strength. Use of phosphoric acid to etch for 15 s and coated with self-etch adhesive system for 20 s achieved the highest bond strength. In either self-etch or total-etch adhesive system, use of phosphoric acid to etch for 15 s and coated with self-etch adhesive system for 20 s achieved optimal bond strength, there was the lowest bond strength when the self-etch adhesive system used as recommended time.
No clinical trial protocols linked to this paper
Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.PICO Elements
No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.
Paper Details
MeSH Terms
Associated Data
No associated datasets or code repositories found for this paper.
Related Papers
Related paper suggestions will be available in future updates.