Implant survival and patient satisfaction of reduced diameter implants made from a titanium-zirconium alloy: A retrospective cohort study with 550 implants in 311 patients.
The aim of the study was to evaluate implant survival of reduced-diameter implants compared to regular-diameter implants. A retrospective evaluation of 154 Straumann Bone Level Roxolid((R)) implants (diameter 3.3 mm) with SLActive((R))-surface in 107 patients, which were inserted between 2009 and 2010 in private practice, was performed. The mean observation period was 22.4 +/- 8.2 months. 396 Straumann SLActive((R)) implants (4.1 mm and 4.8 mm) in 204 patients, with an observation period of 28.4 +/- 10.1 months served as control group. Implant survival rate, resonance frequency analysis and patient satisfaction were evaluated. The implant survival rate was 97.4% in the test vs. 98.5% in the control group. Resonance frequency analysis showed statistically significant lower values for the reduced-diameter implants. Patient satisfaction showed no significant difference between the test and the control group. Reduced-diameter implants displayed high survival rates during the period investigated and represent a convincing treatment alternative. Long-term follow-up investigations confirmed the high implant survival rates of 96.8% (after 69.7 +/- 12.3 months) in the test group and 98.5% (after 76.0 +/- 13.6 months) in the control group.
No clinical trial protocols linked to this paper
Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.PICO Elements
No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.
Paper Details
MeSH Terms
Associated Data
No associated datasets or code repositories found for this paper.
Related Papers
Related paper suggestions will be available in future updates.