2017 Journal of periodontology

Influence of Laser-Microtextured Surface Collar on Marginal Bone Loss and Peri-Implant Soft Tissue Response: A Systematic Review and Meta-Analysis.

, , , ,

Journal of periodontology Vol. 88 (7) : 651-662 • Jul 2017

BACKGROUND: A laser-microtextured surface (LMS) dental implant collar appears to promote a more tooth-like gingival collagen fiber attachment, which may help to stabilize peri-implant tissues. The purpose of this systematic review is to assess the clinical effect of an LMS versus non-LMS collar on crestal bone level and peri-implant soft tissue response. METHODS: Electronic and manual literature searches were performed by two independent reviewers for articles written in English up to December 2016. Studies were included if they were human clinical trials with the purpose of evaluating the impact of an LMS collar on peri-implant hard and soft tissues. Cumulative marginal bone loss (MBL), probing depth (PD), and survival rate (SR) with 95% confidence intervals (CIs) were calculated to show the performance of LMS implant collars. MBL, PD, and SR data were analyzed with a random effects model to compare the influence of LMS collars with non-LMS collars (e.g., roughened surface and machined surface). RESULTS: Fifteen human clinical studies (three randomized controlled trials, six cohort studies, and six case series) with 772 implants met the inclusion criteria. For the overall data, the weighted mean MBL was 0.72 mm (95% CI: 0.59 to 0.85 mm), PD was 1.81 mm (95% CI: 1.13 to 2.49 mm), and SR was 0.97 (95% CI: 0.95 to 0.98). MBL around an LMS collar was significantly less than around machined-surface collars (weighted mean difference [WMD]: -0.77; 95% CI: -1.01 to -0.52; I(2) = 95.2%; P <0.001). PD in the LMS group was significantly shallower than in the machined-surface group (WMD: -1.34; 95% CI: -1.62 to -1.05; I(2) = 81.4%; P <0.001). However, no statistically significant difference was detected for MBL between the LMS and roughened-surface groups (WMD: -0.04; 95% CI: -0.16 to 0.08; I(2) = 0.0%; P = 0.75). No statistically significant difference was found for SR between the LMS and non-LMS groups (risk ratio: 1.01; 95% CI: 0.97 to 1.04; I(2) = 0.0%; P = 0.91). CONCLUSIONS: Meta-analysis showed that an LMS collar can reduce the amount of MBL and PD compared with a machined-surface collar. Due to high heterogeneity between the included studies, results should be interpreted cautiously.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.