2017 Medical principles and practi…

An in vitro Comparison of Bond Strength of Different Sealers/Obturation Systems to Root Dentin Using the Push-Out Test at 2 Weeks and 3 Months after Obturation.

, , , ,

Medical principles and practice : international journal of the Kuwait University, Health Science Centre Vol. 26 (5) : 464-469 • Jan 2017

OBJECTIVE: To evaluate the push-out bond strength and failure modes of different sealers/obturation systems to intraradicular dentin at 2 weeks and 3 months after obturation compared to AH Plus(R)/gutta-percha. MATERIALS AND METHODS: A total of 180 root slices from 60 single-canal anterior teeth were prepared and assigned to 5 experimental groups (n = 36 in each group), designated as G1 (AH Plus(R)/gutta-percha), G2 (TotalFill BC sealer/BC-coated gutta-percha), G3 (TotalFill BC sealer/gutta-percha), G4 (EndoREZ(R) sealer/EndoREZ(R)-coated gutta-percha), and G5 (EndoREZ(R) sealer/gutta-percha). Push-out bond strengths of 18 root slices in each group were assessed at 2 weeks and the other 18 at 3 months after obturation using a universal testing machine. Data were analyzed using repeated measures ANOVA. An independent t test was used to compare the mean push-out bond strength for each group at 2 weeks and 3 months after obturation. RESULTS: The mean push-out bond strengths of G4 and G5 were significantly lower than those of G1, G2, and G3 (p < 0.05) at both 2 weeks (G1: 1.46 +/- 0.29 MPa, G2: 1.74 +/- 0.43 MPa, G3: 1.74 +/- 0.43 MPa, G4: 0.66 +/- 0.31 MPa, G5: 0.74 +/- 0.47 MPa) and 3 months after obturation (G1: 1.70 +/- 1.05 MPa, G2: 3.69 +/- 1.20 MPa, G3: 2.84 +/- 0.83 MPa, G4: 0.14 +/- 0.05 MPa, G5: 0.24 +/- 0.10 MPa). The mean push-out bond strengths of G2 (3.69 +/- 1.20 MPa) and G3 (2.84 +/- 0.83 MPa) were higher at 3 months compared to 2 weeks after obturation (G2: 1.74 +/- 0.43 MPa, G3: 1.33 +/- 0.29 MPa). CONCLUSION: The TotalFill BC obturation system (G2) and the TotalFill BC sealer/gutta-percha (G3) showed comparable bond strength to AH Plus(R). Their bond strength increased over time, whereas the EndoREZ(R) obturation system (G4) and EndoREZ sealer (G5) had low push-out bond strength which decreased over time.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers