2017 Implant dentistry

In Vivo Evaluation of Dual Acid-Etched and Grit-Blasted/Acid-Etched Implants With Identical Macrogeometry in High-Density Bone.

, , , , ,

Implant dentistry Vol. 26 (6) : 815-819 • Dec 2017

PURPOSE: Based on the current evidence, the effect of implant macrogeometry has a significant influence on osseointegration. Thus, this study evaluated histomorphometrically and histologically the bone response to acid-etched in comparison to grit-blasted/acid-etched (GB) and machined control (C) surfaced implants possessing identical macrogeometry placed in high-density bone. MATERIALS AND METHODS: Implant surface topography of the 3 different surfaced implants has previously been characterized. The macrogeometry of the implants were conical, and healing chambers were created in the cortical regions. The 3 groups were placed in the external mandibular body of adult male sheep (n = 5). After 6 weeks in vivo, all samples were retrieved for histologic observation and histomorphometry (eg, bone-to-implant contact [BIC] and bone area fraction occupancy [BAFO]). RESULTS: No statistical difference was observed for BIC and for BAFO, although there was a tendency that the mean values for BAFO was higher for the textured surface groups. CONCLUSIONS: It is suggested that the effect of surface topography is minimal in high-density bone and osseointegration seemed to be macrogeometry dependent.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.