2018 Operative dentistry

Assessing the Appearance and Fluorescence of Resin-Infiltrated White Spot Lesions With Caries Detection Devices.

,

Operative dentistry Vol. 43 (1) : E10-E18 • Jan 2018

OBJECTIVE: This in vitro study examined the effectiveness of caries detector devices in assessing the ability of resin infiltration (RI) (Icon, DMG-Hamburg, Hamburg, Germany) to improve the optical properties of enamel white spot lesions (WSLs). METHODS AND MATERIALS: Ten caries-free third molars were used. Photographs, a subjective visual assessment of the photographs, fluorescent camera (FC) images using the Spectra (Air Techniques, Melville, NY, USA), and laser fluorescent (LF) readings using the DIAGNOdent (KaVo, Biberach, Germany) were obtained from each tooth's buccal surface. Specimens were coated with nail polish leaving a rectangular window on the buccal surface and placed in pH 4.5 lactic acid gel for two weeks to create a WSL. The WSLs were analyzed by the same methods. RI was applied to half of each WSL; final photographs were then taken, and caries detector assessments were conducted. FC images were converted to grayscale, and the fluorescent image's brightness intensity was measured using ImageJ. Data were analyzed with analysis of variance and Tukey-Kramer honestly significant difference test. Significance was set at alpha=0.05. RESULTS: Subjective assessment of the photographs showed that RI improved the appearance of the WSLs so that they resembled intact enamel. Mean FC-brightness intensities for intact, demineralized, and demineralized RI-treated areas were 159.6 +/- 9.2, 123.4 +/- 7.2, and 160.9 +/- 11.5, respectively. There were no significant differences in fluorescent intensity between the intact and RI areas ( p=0.58). The demineralized areas had significantly lower fluorescent intensity than both the RI-treated and intact areas ( p<0.001). LF values did not differ significantly between intact, demineralized, or RI-treated areas. CONCLUSIONS: This study demonstrates the ability of RI to restore artificial WSLs to the esthetics and fluorescence of intact enamel. The FC can be used to assess the optical properties of WSLs and the impact of RI on these properties.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.