Fatigue resistance of all-ceramic fixed partial dentures - Fatigue tests and finite element analysis.

, , , , , ,

Dental materials : official publication of the Academy of Dental Materials Vol. 34 (3) : 494-507 • Mar 2018

OBJECTIVE: To estimate the fatigue resistance of a new translucent zirconia material in comparison to lithium disilicate for 3-unit fixed partial dentures (FPDs). METHODS: Eighteen 3-unit FPDs (replacement of first upper molar) with a connector size of 4mmx4mm were dry milled with a five-axis milling machine (Zenotec Select, Wieland, Germany) using discs made of a new translucent zirconia material (IPS e.max ZirCAD MT, Ivoclar Vivadent). Another 9 FPDs with a reduced connector size (3mmx4mm) were milled. The zirconia FPDs were sintered at 1500 degrees C. For a comparison, 9 FPDs were made of IPS e.max Press, using the same dimensions. These IPS e.max Press FPDs were ground from a wax disc (Wieland), invested and pressed at 920 degrees C. All FPDs were glazed twice. The FPDs were adhesively luted to PMMA dies with Multilink Automix. Dynamic cyclic loading was carried out on the molar pontic using Dyna-Mess testing machines (Stolberg, Germany) with 2x10(6) cycles at 2Hz in water (37 degrees C). Two specimens per group and load were subjected to decreasing load levels (at least 4) until the two specimens no longer showed any failures. Another third specimen was subjected to this load to confirm the result. All the specimens were evaluated under a stereo microscope (20x magnification). The number of cycles reached before observing a failure, and their dependence on the load and on the material, were modeled, using a Weibull model. This made it possible to estimate the fatigue resistance as the maximum load for which one would observe less than 1% failure after 2x10(6) cycles. In addition to the experimental study, Finite Element Modeling (FEM) simulations were conducted to predict the force to failure for IPS e.max ZirCAD MT and IPS e.max Press with a reduced cross-section of the connectors. RESULTS: The failure mode of the zirconia FPDs was mostly the fracture of the distal connector, whereas the failure mode of the lithium disilicate FPDs observed to be the fracture of the connectors or multiple cracks of the pontic. The fatigue resistance with 1% fracture probability was estimated to be 488N for the IPS e.max ZirCAD MT FPDs (453N for repeated test), 365N for IPS e.max ZirCAD MT FPDs with reduced connector size and 286N for the e.max Press FPDs. All three IPS e.max ZirCAD groups statistically performed significantly better than IPS e.max Press (p<0.001). On the other hand, no significant difference could be established between the two IPS e.max ZirCAD MT3 groups with a 4mmx4mm connector size (p>0.05). The allowable maximum principal stress (sigma(max)) which did not lead to failure during fatigue testing for IPS e.max ZirCAD MT3 was calculated between 208MPa and 223MPa for FPDs with 4mmx4mm connectors for 2x10(6) cycles. This value could also be verified for the FPDs of the same material with 3mmx4mm connectors. On the other hand fatigue strength in terms of sigma(max) at 2x10(6) cycles of IPS e.max Press was calculated to be between 78 and 90MPa. SIGNIFICANCE: The fatigue resistance of the translucent zirconia 3-unit FPDs was about 60-70% higher than that of the lithium disilicate 3-unit FPDs, which may justify their use for molar replacements, provided that a minimal connector size of 4mmx4mm is observed. Even with a limited number of specimens (n=9) per group it was possible to statistically differentiate between the tested groups.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.