2018 American journal of orthodont…

Comparison of digital intraoral scanners and alginate impressions: Time and patient satisfaction.

, , , ,

American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics Vol. 153 (4) : 534-541 • Apr 2018

INTRODUCTION: Recent technological advances have made intraoral scans and digital models a possibility and a promising alternative to conventional alginate impressions. Several factors should be examined when considering an intraoral scanner, including patient acceptance and efficiency. The objectives of this study were to assess and compare patient satisfaction and time required between 2 intraoral scanners and conventional alginate impressions. METHODS: An initial pilot study was completed to create a valid and reliable survey instrument that would measure 3 areas of patient satisfaction with the impression experience. A visual analog scale survey was developed and administered to 180 orthodontic patients receiving 1 of 3 types of impressions: (1) iTero Element intraoral scan (Align Technologies, San Jose, Calif), n = 60; (2) TRIOS Color intraoral scan (3Shape, Copenhagen, Denmark), n = 60; and (3) conventional alginate impression (imprEssix Color Change; Dentsply Sirona, York, Pa), n = 60, and the time required to obtain the impressions was recorded. RESULTS: Reliability was evaluated with intraclass correlation coefficient values for 17 paired questionnaires, and all questions were found to be reliable (intraclass correlation coefficient, >/=0.65). For the main study, 180 subjects completed timed impressions and surveys. Data indicated that subjects receiving intraoral scans preferred the digital impressions, and subjects receiving alginate impressions were neutral regarding impression preference, and that efficiency varied based on the impression method. CONCLUSIONS: Intraoral scanners are accepted by orthodontic patients, and they have comparable efficiency with conventional impression methods depending on the type of scanner.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
+8 more
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.