PURPOSE: The aim of this study was to analyze and compare the stress distribution patterns of different implant and restorative materials in the supporting tissue and implants. MATERIALS AND METHODS: Twelve different implant/bone models were created using SolidWorks 2015 software (SolidWorks Corp) and analyzed using the finite element method. Straumann Bone Level implants with zirconia abutments and single-piece Straumann PURE Ceramic implants (Institute Straumann) restored with lithium disilicate glass-ceramic and zirconia ceramic cement-retained crowns were evaluated. A 118.2-N load was applied to the coronal aspect of the buccal cusp at a 75.8-degree angle in relation to the occlusal plane. Principal stress values for cortical and trabecular bone and the equivalent von Mises stress values for implants and frameworks were calculated. RESULTS: Zirconia (ZrO(2)) implant models showed lower principal stress values than the commercially pure titanium (cpTi) and titanium-zirconium (TiZr) implant models in cortical bone. All models showed similar principal stress values in trabecular bone. Von Mises stress values at the cpTi and TiZr implants were similar; however, values observed of ZrO(2) implants were higher. TiZr implants of 3.3 mm diameter showed similar strength to 4.1-mm-diameter cpTi implants. Both zirconia and lithium disilicate glass-ceramic frameworks transferred similar von Mises stress values in the supporting tissue of implant-supported prostheses. CONCLUSION: Narrow-diameter TiZr implants may be preferred for patients who have insufficient bone volume without bone augmentation procedures due to the material's enhanced biomechanical properties. ZrO(2) implants may be a suitable alternative for esthetic regions. Further clinical studies are recommended to investigate the long-term performance of TiZr and ZrO(2) implants.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.