2019 Journal of prosthodontics : o…

The Conometric Concept: A Two-Year Follow-Up of Fixed Partial CEREC Restorations Supported By Cone-In-Cone Abutments.

, , , ,

Journal of prosthodontics : official journal of the American College of Prosthodontists Vol. 28 (2) : e780-e787 • Feb 2019

PURPOSE: To evaluate the performance of definitive, implant-supported, lithium disilicate fixed dental prostheses (LS(2) FDPs) manufactured with a computer-assisted design/computer-assisted manufacturing (CAD/CAM) system. All patients received two-unit restorations placed in posterior regions, supported by osseointegrated implants with cone-in-cone connection abutments. MATERIALS AND METHODS: Two implants (Ankylos) were placed into healed sites or fresh extraction sockets in the maxillary/mandibular posterior regions of partially edentulous patients. Definitive digital impressions were made 3 months after surgery. Twenty-four patients received fixed monolithic LS(2) restorations manufactured with the CEREC system. All restorations were connected to the implants using cone-in-cone connection abutments. Peri-implant pocket depths were recorded for 2 years at each follow-up visit. Esthetic, functional, and biologic United States Public Health Services (USPHS) parameters modified by the FDI World Dental Federation study design were assessed yearly until the last follow-up appointment. The opposing dentitions were identified by type of restoration and supporting structures at the time of placement of the definitive restorations and at the 2-year follow-up visits. RESULTS: One patient (4.16%) moved to an unknown location during the study. A total of 23 FDPs (95.8%) supported by 46 implants reached the 2-year follow-up. None of the prostheses failed, or became loose or detached. No significant difference involving probing levels between the experimental times were found. CONCLUSIONS: The results of this research indicated that the abutment-prostheses connection using a cone-in-cone approach was successful within the 2-year period of this study. None of the studied monolithic LS(2) glass-ceramic prostheses milled using the CEREC CAD/CAM system fractured or became detached.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.