2020 Journal of prosthodontics : o…

Impact of Occlusal Intercuspal Angulation on the Quality of CAD/CAM Lithium Disilicate Crowns.

, , , ,

Journal of prosthodontics : official journal of the American College of Prosthodontists Vol. 29 (3) : 219-225 • Mar 2020

PURPOSE: Modification of intercuspal angulation (ICA) influences the amount of tooth structure removal, which may impact the retention and resistance form of the preparation. This study evaluated the impact of ICA on the marginal gap of CAD/CAM crowns and the influence that tooth structure removal, caused by variation of ICA, has on the resistance and retention form of the preparation. MATERIALS AND METHODS: Sixty ivorine molars were manufactured with various ICAs (100 degrees , 110 degrees , 120 degrees , 140 degrees , 160 degrees , and 180 degrees ; 10 per group). The preparations were digitized using an intraoral scanner, and the crowns were designed using a design software. The designed crowns were then manufactured from lithium disilicate using a 3-axis milling machine, with the "detailed mode" selected for the manufacturing. The marginal gap of each crown was evaluated using a stereomicroscope at 20x magnification. Then, the marginal integrity and the resistance form of the preparation were assessed by tactile-visual evaluation, and they were given a categorical score. Crowns were then secured on their associated preparations using a temporary luting agent, and retention force was measured on a universal testing machine under tension with a 0.5 mm/min crosshead speed. Wilcoxon test followed by post-hoc tests (alpha = 0.05) were used to evaluate the impact of the ICA on the marginal gap and the retention form of the preparation. Fisher's exact test followed by post-hoc tests (alpha = 0.05) were used to assess the impact of the occlusal preparation design on the marginal integrity and the resistance form of the preparation. RESULTS: The marginal gap was significantly larger for ICA-180 preparations (72 mum), compared to the other groups (ICA-180 vs ICA-100, ICA-110, ICA-120, and ICA-160 p = 0.0001; ICA-180 vs. ICA-140 p = 0.0017). None of the crowns for ICA-180 preparations had clinically acceptable resistance form. Preparations with ICAs of 100 degrees , 110 degrees , and 120 degrees had a significantly higher value of retention than the other groups (ICA-100 vs. ICA-120 p = 0.0119; ICA-100 vs. ICA-140, ICA-160, and ICA-180 p < 0.0001; ICA-110 vs. ICA-140, ICA-160, and ICA-180 p = 0.0001; ICA-120 vs. ICA-180 p = 0.0017). CONCLUSIONS: Crowns fabricated for preparations with various ICAs had clinically acceptable marginal adaptation. Variation in ICA impacts the loss of tooth structure. This loss of tooth structure may influence the resistance and retention form of the preparation.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.