PURPOSE: To assess the clinical performance of single crowns in the posterior maxilla supported by either 11-mm-long implants combined with maxillary sinus floor elevation surgery or 6-mm-long implants during a 5-year follow-up period. MATERIALS AND METHODS: A total of 38 consecutive patients, missing a premolar or a molar in the posterior maxilla and residual bone height underneath the maxillary sinus between 6 to 8 mm, were included. Subjects were randomly allocated to receive one 11-mm-long implant in combination with maxillary sinus floor augmentation or to receive one 6-mm-long implant without any grafting. A total of 41 implants (21 implants in 20 patients in the 6-mm group, and 20 implants in 18 patients in the 11-mm group) were placed and subsequently restored after 3 months with custom-made titanium abutments and cemented zirconia-based porcelain crowns. Both groups were followed by clinical (implant survival, restoration survival, complications, pocket probing depth and presence of plaque, calculus, bleeding and peri-implant inflammation) and radiographic examinations up to 5 years. The patient satisfaction was scored before treatment, and 12 and 60 months after functional implant restoration. RESULTS: One patient (11-mm group) died before the 12-month evaluation and one patient (6-mm group) moved away. In addition, one patient in the 6-mm group lost one implant and no implants were lost in the 11-mm group. Two patients lost three restorations in the 6-mm group and no restorations were lost in the 11-mm group. From loading until the 60-month assessment, the mean marginal bone loss in the 6-mm group and the 11-mm group was 0.12 +/- 0.36 mm and 0.14 +/- 0.63 mm, respectively, without a significant difference (mean difference 0.02 mm; 95% CI -0.32 to 0.37; P = 0.884). Implant loss, restoration loss, screw loosening and porcelain chipping were defined as complications. Four patients in the 6-mm group and one patient in the 11-mm group had one or more complications, without a significant difference between the groups (95% CI 0.019 to 0.244; P = 0.198). The patient satisfaction was high in both groups (mean overall satisfaction in the 6-mm and the 11-mm groups was 9.4 +/- 0.8 and 9.2 +/- 0.8, respectively; mean difference 0.2; 95% CI -0.33 to 0.76; P = 0.434). CONCLUSIONS: Reconstructions performed using an 11-mm implant combined with maxillary sinus floor augmentation or a 6-mm implant in the resorbed posterior maxilla are equally successful in supporting a single restoration over 5 years.
No clinical trial protocols linked to this paper
Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.PICO Elements
No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.
Paper Details
MeSH Terms
Associated Data
No associated datasets or code repositories found for this paper.
Related Papers
Related paper suggestions will be available in future updates.