2019 Clinical implant dentistry an…

Failure analysis of high performance polymers and new generation cubic zirconia used for implant-supported fixed, cantilevered prostheses.

, ,

Clinical implant dentistry and related research Vol. 21 (6) : 1132-1139 • Dec 2019

BACKGROUND: The load-to-failure performance of computer-assisted design and computer-assisted manufacturing (CAD-CAM) high performance polymers (HPP) and new generation cubic zirconia (Zir) material when used with titanium (Ti) bases for implant-supported fixed prostheses with cantilevers is unknown. PURPOSE: To evaluate the load-to-failure performance of different CAD-CAM fabricated HPP and a new generation cubic Zir in a cantilevered situation when used with Ti bases. MATERIALS AND METHODS: Five specimens with a Ti base and five specimens without Ti bases were fabricated from seven different CAD-CAM HPPs (100% PEEK [J and CP], 80% PEEK with 20% filler [BRE], 80% PEKK with 20% filler [PK], ceramic reinforced PEEK [ZZ], interlaced fiberglass and resin [TR], fiber-composite material [T]). Five specimens with Ti base and two specimens without Ti base were prepared from a new generation cubic Zir (DD) and a 3Y-TZP Zir (FZR) as the control group (N = 84). All specimens (8 x 7 x 30 mm) were stabilized using a clamp attached to the first 20 mm of each specimen for a 10 mm cantilever. Static loading was applied vertically on the cantilever and the maximum load-to-failure values (N) were analyzed using a two-way ANOVA and t-test (alpha = .05). RESULTS: HPP and Zir specimens without Ti bases had significantly higher load-to-failure values than Ti based ones in all groups (P < .05). PK with Ti base had significantly lower load-to-failure values than other materials (P < .001). FZR showed significantly higher load-to-failure values than all HPPs and DD (P < .001). CONCLUSIONS: Load-to-failure values of HPPs and Zir were lower when Ti bases were used. New generation cubic Zir and all HPPs had lower load-to-failure values than FZR. HPPs performance varied among tested materials. PEKK with Ti base had the lowest load-to-failure value.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.