2020 Clinical implant dentistry an…

Cleaning potential of different air abrasive powders and their impact on implant surface roughness.

, , , , ,

Clinical implant dentistry and related research Vol. 22 (1) : 96-104 • Feb 2020

BACKGROUND: Implant surface roughness after air abrasive therapy has not been measured precisely in previous research. Debridement with air abrasion facilitates the mechanical removal of bacterial biofilms but may damage implant surfaces on a microscopic level. PURPOSE: This study aimed to investigate the cleaning potential of various air abrasive powders and their effect on titanium implant surfaces. MATERIALS AND METHODS: Twenty implants coated with red ink were inserted into three-dimensional printed circumferential bone defect models. Treatment was completed with three types of air abrasive powders: sodium bicarbonate (SB), glycine, and erythritol for 60 seconds. Water alone was used as control. The percentage of remaining ink was assessed using digital photography and graphic software. Implant surface topography/roughness was quantified using optical profilometry and examined via scanning electron microscopy. The microscopic analysis was performed at two implant areas: collar (Laser-Lok surface) and threads. RESULTS: The cleaned surfaces (%, mean +/- SD) after treatment with SB, glycine, and erythritol accounted for 49.3 +/- 3.6%, 33.1 +/- 1.2%, and 25.1 +/- 0.7%, respectively. Statistically significant differences were found between all groups (P < .001). SB was the only powder that significantly increased the implant roughness (S(a) ) on both the implant collar (1.53-2.10 mum) and threads (3.53-4.20 mum). Regardless of the abrasive powder used, the collar, emerging implant surfaces from the defect base, and surfaces beneath implants threads exhibited more post-treatment residual ink. CONCLUSION: Large-sized powder showed the greatest cleaning capacity, but caused more alterations to the implant surface. Glycine and erythritol displayed no significant changes in surface roughness, however, demonstrated a limited ink removal capacity.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.