2019 Journal of long-term effects …

Stress and Strain Distribution Patterns in Bone around Tissue- and Bone-Level Implant-Supported Mandibular Overdentures Using Three-Dimensional Finite-Element Analysis.

,

Journal of long-term effects of medical implants Vol. 29 (3) : 175-181 • Jan 2019

Our aim is to investigate the effect of implant placement in two positions (bone level and tissue level) on stress and strain distribution around mandibular implant overdentures. We use two models of mandibular overdentures. Taper implants are inserted and collimated between the lateral and canine teeth. All structures are scanned, digitized, and three-dimensioned (3D) model designed. We apply a vertical load of 100 N simultaneously on the central fossa of the mandibular first molar of the two models (bone- and tissue-level implant). Stress and strain values are obtained using 3D finite-element analysis (FEA). In comparison to the tissue-level model, bone-level implants can reduce overdenture movement and tension by 0.8 mum. The results of this study show that using bone-level implants can reduce tension on the prosthesis part of the overdenture and the bone around the implants as well as on the movement of the distal end of the mandibular overdenture. We found that bone strain occurred around implants within physiological limits in model 1 (bone level) compared to model 2 (tissue level). This shows that the distribution of physical forces in bone-level implants generally produces better results than those of issue-level implants. However, more research on the subject is needed.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.