2020 Quintessence international (B…

D-PLEX500: a local biodegradable prolonged release doxycycline-formulated bone graft for the treatment for peri-implantitis. A randomized controlled clinical study.

, , ,

Quintessence international (Berlin, Germany : 1985) Vol. 51 (7) : 546-553 • Jan 2020

OBJECTIVES: In the present pilot, multicenter, randomized, single-blinded, controlled study, surgical treatment with or without the administration of D-PLEX500 (a biodegradable prolonged release local doxycycline formulated with beta-tricalcium phosphate bone graft) was accessed for the treatment of peri-implantitis. METHOD AND MATERIALS: Subjects undergoing surgical treatment for intrabony peri-implantitis defects after flap elevation were randomly assigned, to adjunct D-PLEX500 placement group or to control group. Clinical and radiographic parameters were measured at 6 and 12 months. RESULTS: Twenty-seven subjects (average age: 64.81 +/- 7.61 years) were enrolled; 14 patients (18 implants) were randomized to the test group and 13 (14 implants) to the control group. There was no difference in plaque scores between the groups. There was no difference in the changes of mean periodontal probing depth between the test and control groups between baseline and the 6-month follow-up, whereas statistically significant difference was observed after 12 months' follow-up when analyzed for all sites averaged. There was a statistically significant difference in the changes of clinical attachment levels and radiographic bone levels between the groups between baseline and 12 months. These improvements were demonstrated when analyzed at both implant and subject levels. Only D-PLEX500 treatment led to improved bone levels at both time points. The improvement in bone levels was significant in the D-PLEX500 treatment group already after 6 months, and further improved over the 12-month follow-up. Implants were lost only in the control group (14%). CONCLUSIONS: D-PLEX500 sustained release local antibiotic formulated with bone filler showed promising results in enabling healing of peri-implantitis lesions. The antibacterial component of the bone graft material might create favorable conditions that enable implant surface decontamination and soft and hard tissue healing over a prolonged period.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.