2021 Journal of prosthodontics : o…

Effect of Milling Protocols on Trueness and Precision of Ceramic Crowns.

, , ,

Journal of prosthodontics : official journal of the American College of Prosthodontists Vol. 30 (2) : 171-176 • Feb 2021

PURPOSE: To investigate the effect of different milling protocols for different ceramic materials on the trueness and precision of milled ceramic crowns. MATERIALS AND METHODS: A definitive impression from a patient requiring a ceramic crown was used to fabricate forty glass ceramic crowns (VITABLOCS mark II, Vita Zahnfabrik) milled with wet, hard milling protocol, and 40 zirconia crowns (inCoris TZI, Dentsply, Sirona) milled with dry, soft milling protocol, using a 5-axis milling machine (inLab MC X5; Dentsply Sirona). Trueness and precision for different crown areas were evaluated with a 3D evaluation software (Geomagic Control X, 3D systems). Statistical analysis was performed between the 2 crown types with independent t-test, and analysis of variances followed by Bonferroni tests among crown areas for each crown. RESULTS: All areas of the glass ceramic crowns had higher trueness than the zirconia crown areas (p < 0.05). Crown areas of each crown type had significantly different trueness values (p < 0.001, F = 175.17 for glass crowns, p < 0.001, F = 35.04 for zirconia crowns). Glass crowns had 3.78 microm precision, while zirconia crowns had 4.12 microm precision, with a precision difference range between the 2 types of crowns from 0.32 microm for the inner surface to 6.5 microm for the marginal surface. CONCLUSIONS: Type of ceramic material and milling protocol affected trueness of the milled crown, with higher trueness for the hardmilled glass crowns than the soft milled zirconia crowns. Soft milled zirconia crowns were generally overmilled in comparison with the reference design and glass crowns. However, glass crowns exhibited more undermilling in thin and deep areas. The crown area affected trueness, with external areas having better trueness than internal areas. The 5-axis milling machine had high precision, which was minimally affected by the ceramic type, milling protocol, or crown area.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.