2021 Journal of oral and maxillofa…

Three-Dimensional Repositioning of the Maxilla in Orthognathic Surgery Using Patient-Specific Titanium Plates: A Case Series.

, , , ,

Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons Vol. 79 (4) : 902-913 • Apr 2021

PURPOSE: Successful orthognathic surgery is fundamentally based on accurately carrying out the intended surgical plan intraoperatively. The purpose of this study was to evaluate the accuracy of bone-borne patient-specific maxillary cutting guides and 3-dimensional (3D)-printed plates in repositioning the maxilla during bimaxillary orthognathic surgery. MATERIALS AND METHODS: This was a retrospective case series consisting of patients who had undergone Le Fort I osteotomy with a patient-specific cutting guide and 3D-printed plate as well as a bilateral sagittal split osteotomy and had 6-week postoperative cone-beam computed tomography studies. The primary outcome variable was the difference between the position of the postoperative maxilla and the virtually planned maxilla measured at 10 landmarks in 3 dimensions. Other study variables included the preoperative diagnosis and planned surgical movement at each landmark. Descriptive statistics were tabulated, and bivariate analyses were performed. RESULTS: A total of 10 patients were included in this study. The mean age was 25.7 +/- 8.1 years, and there were 5 female patients. The median planned surgical movement was 0.350 mm on the x-axis (right-left), 3.750 mm on the y-axis (anterior-posterior), and 1.704 mm on the z-axis (superior-inferior). The median absolute discrepancy between the postoperative position and the planned position on the x-axis, y-axis, and z-axis was 0.638, 0.798, and 0.481 mm, respectively. There was no significant difference in the discrepancies between the x-axis and y-axis (P = .575), x-axis and z-axis (P = .332), and y-axis and z-axis (P = .114). CONCLUSIONS: Using a patient-specific cutting guide and 3D-printed plate when performing Le Fort I osteotomy allows for accurate 3-dimensional positioning of the maxilla in accordance with the surgical plan.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.