The objective of this systematic review was to evaluate the stability and complications of tooth-borne (TB), bone-borne (BB) and hybrid (TB-BB) appliances in surgically assisted rapid maxillary expansion (SARME). Database searches were conducted (PubMed, Embase, Cochrane Library and SciELO), as well as a grey literature search (Google Scholar) and hand searches of reference lists. Forty-six articles were included after study selection (kappa=0.854). After eligibility assessment, 16 articles and one article from the grey literature were processed (kappa=0.866) and six articles were selected by hand searching, for a total of 23 articles included. Regarding stability, TB appliances showed width relapse rates ranging from 4 to 35% in canines, from 1 to 37% in premolars and from 0.2 to 49.5% in molars. In BB appliances, width relapse rates were 1.7-21% in canines, 1.5% in premolars and 4.6-11.5% in molars. In hybrid appliances, the width relapse rate was 14% in premolars, with a 1.8% overexpansion reported in the molar region. In TB and BB appliances, skeletal relapse rates were similar on the nasal floor (11-53% and 41.6%, respectively) and at the level of the maxilla (18% and 16%, respectively). The most common complications were bone resorption in TB appliances (18.14%) and appliance-related complications in BB appliances (17.9%). The risk of bias was high in 19 studies, medium in three studies and low in one study. The TB and BB appliances used in SARME were considered to have a high long-term stability. BB appliances appeared to have fewer relapses than TB appliances due to a more parallel distribution of forces exerted. However, relapse appears to be highly influenced by postorthodontic treatments, where arch-form coordination is achieved in the consolidation period with the purpose of overexpansion correction, alignment and final vertical adjustments. Further randomised controlled trials with long-term data and large sample sizes are needed to support evidence-based clinical decision-making and to allow meta-analytic studies of stability outcomes regarding the type of anchorage in SARME.
No clinical trial protocols linked to this paper
Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.PICO Elements
No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.
Paper Details
MeSH Terms
Associated Data
No associated datasets or code repositories found for this paper.
Related Papers
Related paper suggestions will be available in future updates.