2021 Journal of prosthodontics : o…

Failure Risk of Short Dental Implants Under Immediate Loading: A Meta-Analysis.

, , , , , ,

Journal of prosthodontics : official journal of the American College of Prosthodontists Vol. 30 (7) : 569-580 • Aug 2021

PURPOSE: Currently, there is no clear clinical evidence that short implants are suitable for immediate loading. Therefore, this meta-analysis aims to evaluate whether immediate loading increases the failure risk of short dental implants. MATERIALS AND METHODS: This meta-analysis was registered at PROSPERO (CRD 42020195890). PubMed, Embase, and Cochrane Library databases were searched to collect all clinical studies comparing the failure rates of short dental implants (<10 mm) and standard implants (>/=10 mm) under the condition of immediate loading and studies comparing the failure rates of short dental implants under immediate loading versus early or delayed loading. All of the clinical studies with available relevant data were eligible for inclusion. The Cochrane Risk of Bias tool was adopted to evaluate the risk of bias for the randomized controlled trial (RCT), while Newcastle-Ottawa Quality Assessment Scale (NOS) was used for the observational studies (OS). The OR value of each included study and its 95% CI were pooled to estimate the failure risk of short dental implants under immediate loading. The heterogeneity among studies was evaluated through Cochran's Q test and I(2) . RESULTS: Seventeen studies, 5 RCTs and 12 OS studies, with a total of 2461 dental implants were analyzed. Four of the RCT studies were of low risk of bias and one was of unclear risk, while all of the OS studies were of moderate or high quality. Compared with standard implants, short implants did not have an increased failure risk under immediate loading (OR: 1.38, 95% CI: 0.67-2.84, p = 0.997, fixed model). In addition, the OR value of implant failure for short implants under immediate loading compared to that for short implants under early or delayed loading was 1.22 (95% CI: 0.33-4.55, p = 0.104, random model), which was also not significantly different. CONCLUSIONS: There is not enough evidence to show that short dental implants under immediate loading may have higher implant failure risk compared to standard implants under immediate loading and short implants under early or delayed loading. Therefore, an immediate loading protocol may not increase the failure risk of short dental implants.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.