2021 Clinical oral implants resear…

Implants sites with concomitant bone regeneration using a resorbable or non-resorbable membrane result in stable marginal bone levels and similar profilometric outcomes over 5 years.

, , , , , ,

Clinical oral implants research Vol. 32 (8) : 893-904 • Aug 2021

OBJECTIVES: To assess clinical and radiographic outcomes as well as the profilometric contour alterations of peri-implant hard and soft tissues around single implants treated with simultaneous guided bone regeneration (GBR) at 5 years. MATERIALS AND METHODS: Twenty-seven patients presenting with a single tooth gap in the esthetic zone received a two-piece implant. GBR was randomly performed using a resorbable (RES) or a non-resorbable membrane (N-RES) combined with a bone substitute material. Follow-up examinations were performed at baseline (BL = crown insertion), 1 year (FU-1), 3 years (FU-3), and at 5 years (FU-5) including clinical and radiographic parameters as well as profilometric changes. Statistics were performed by means of parametric and nonparametric tests. RESULTS: At 5 years, 20 out of 27 patients (9 RES, 11 N-RES) were re-examined. Median values for probing depth changed insignificantly between BL and FU-5 in both groups. The median marginal bone levels were located 0.23 mm (0.06; 0.46; RES) and 0.17 mm (0.13;0.28; N-RES) below the implant shoulder at FU-5 (changes over time p < .05). The calculated median profilometric change between BL and FU-5 was -0.28 mm (-0.53;-0.20; RES; p = .016) and -0.24 mm (-0.43;0.08; N-RES; p = .102; intergroup p = .380). The horizontal bone thickness decreased significantly between re-entry and FU-5 for group RES at all measured levels (p < .05) measuring 0.87 mm (0.0; 2.05) at the implant shoulder, whereas the decrease for group N-RES was insignificant (p = .031) with 0 mm (0; 0.84) at the implant shoulder at 5 years. CONCLUSIONS: Implants sites with concomitant GBR using a resorbable or non-resorbable membrane revealed stable marginal bone levels and clinical outcomes. Profilometric changes were clinically negligible over 5 years. The observed change in hard tissue thickness was partially compensated by an increase in soft tissue thickness.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.