2021 Radiation oncology (London, E…

Correlation between the gamma passing rates of IMRT plans and the volumes of air cavities and bony structures in head and neck cancer.

, , , , , ,

Radiation oncology (London, England) Vol. 16 (1) : 134 • Jul 2021

BACKGROUND: Both patient-specific dose recalculation and gamma passing rate analysis are important for the quality assurance (QA) of intensity modulated radiotherapy (IMRT) plans. The aim of this study was to analyse the correlation between the gamma passing rates and the volumes of air cavities (V(air)) and bony structures (V(bone)) in target volume of head and neck cancer. METHODS: Twenty nasopharyngeal carcinoma and twenty nasal natural killer T-cell lymphoma patients were enrolled in this study. Nine-field sliding window IMRT plans were produced and the dose distributions were calculated by anisotropic analytical algorithm (AAA), Acuros XB algorithm (AXB) and SciMoCa based on the Monte Carlo (MC) technique. The dose distributions and gamma passing rates of the targets, organs at risk, air cavities and bony structures were compared among the different algorithms. RESULTS: The gamma values obtained with AAA and AXB were 95.6 +/- 1.9% and 96.2 +/- 1.7%, respectively, with 3%/2 mm criteria (p > 0.05). There were significant differences (p < 0.05) in the gamma values between AAA and AXB in the air cavities (86.6 +/- 9.4% vs. 98.0 +/- 1.7%) and bony structures (82.7 +/- 13.5% vs. 99.0 +/- 1.7%). Using AAA, the gamma values were proportional to the natural logarithm of V(air) (R(2) = 0.674) and inversely proportional to the natural logarithm of V(bone) (R(2) = 0.816). When the V(air) in the targets was smaller than approximately 80 cc or the V(bone) in the targets was larger than approximately 6 cc, the gamma values of AAA were below 95%. Using AXB, no significant relationship was found between the gamma values and V(air) or V(bone). CONCLUSION: In clinical head and neck IMRT QA, greater attention should be paid to the effect of V(air) and V(bone) in the targets on the gamma passing rates when using different dose calculation algorithms.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.