2022 Dental materials journal

Fracture resistance and failure mode of layered translucent zirconia with different crown designs.

, ,

Dental materials journal Vol. 41 (1) : 54-59 • Feb 2022

This study investigated the impact of different veneering design on the fracture resistance and failure mode of layered translucent zirconia crowns, compared to the full monolithic zirconia crowns. Ninety crowns with different designs were divided into six groups (n=15); one fully contoured monolithic crown (FMC), one fully veneered with porcelain (FVC), or four partially veneered designs. All crowns were thermo-cycled, and then loaded to failure in a universal testing machine. The fracture resistance (N) and fracture modes were assessed. One-way ANOVA was performed followed by Tukey's multiple comparison (alpha<0.05). Results demonstrated that all the tested partially veneered designs exhibited enhanced fracture resistances and were comparable to that of the full-contour monolithic translucent zirconia crowns.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers