INTRODUCTION: This study assessed the amount of unprepared surface areas at the apical 4-mm segment of the root canal after a planned preparation based on cone-beam computed tomography (CBCT) measurements. METHODS: Eighteen posterior mandible segments were obtained from cadavers and scanned using CBCT and micro-computed tomographic (micro-CT) imaging. CBCT images were used to measure the largest initial canal diameter from 29 root canals of premolars at 1, 2, 3, and 4 mm short of the apical foramen. Each measurement was used to select a master apical instrument with size/taper that was 1 diameter larger to prepare the apical 4 mm of each particular root canal. A post-preparation micro-CT scan was obtained, and the unprepared canal areas were calculated. RESULTS: A very high amount of surface areas over the apical 4 mm of the root canal was included in the final preparation (mean >90%). The unprepared areas ranged from as low as 3.7% to a maximum of 14.6% (mean and median, 9.2% and 9.1%, respectively). CONCLUSIONS: The proposed planned apical root canal preparation resulted in optimized root canal shaping with a substantial amount of prepared surface areas. The protocol used also resulted in a conservative canal enlargement using final instruments that were 1 size larger than the initial largest canal diameter.