2022 American journal of orthodont…

Comparison of 3-dimensional printing technologies on the precision, trueness, and accuracy of printed retainers.

, , , , ,

American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics Vol. 161 (4) : 582-591 • Apr 2022

INTRODUCTION: This study aimed to evaluate the differences in the precision, trueness, and accuracy of 3-dimensional (3D) printed clear orthodontic retainers fabricated using printer systems with different printing technologies. METHODS: Retainers (n = 15) were 3D printed using 4 different printers: stereolithography (SLA), digital light processing (DLP), continuous DLP, and polyjet photopolymer (PPP) printers. Printed retainers were transformed into a digital image through a cone-beam computed tomography scan and compared with the original image using 3D superimposition analysis software. At previously chosen landmarks (R6, L6, R3, L3, R1, and L1), intaglio surfaces of the retainers were compared to that of the reference model. The intercanine and the intermolar width measurements were also assessed. A discrepancy of up to 0.25 mm between the printed retainer and the reference retainer intaglio surfaces indicated accuracy and clinical acceptability. Precision and trueness were also determined. Root mean square and percent of points within the tolerance level were calculated for precision and trueness for each retainer. Statistical significance was set at P <0.05. RESULTS: Interrater correlation coefficient indicated good agreement. Statistically significant differences were found between printer types among the 6 landmarks and the arch width measurements. When evaluating tolerance level and root mean square, statistically significant differences in median precision and trueness among each printer type were found. CONCLUSION: Retainers fabricated by SLA, DLP, continuous DLP, and PPP technologies were shown to be clinically acceptable and accurate compared to the standard reference file. Based on both high precision and trueness, SLA and PPP printers yielded the most accurate retainers.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers