2022 American journal of orthodont…

Miniscrews for orthodontic anchorage: analysis of risk factors correlated with the progressive susceptibility to failure.

, , , ,

American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics Vol. 162 (4) : e192-e202 • Oct 2022

INTRODUCTION: The phenomenon of orthodontic anchorage miniscrews loosening after being implanted several times happens in daily clinical practice, and the reasons need to be traced. This study aimed to investigate the underlying risk factors influencing the progressive susceptibility of orthodontic miniscrews to failure. METHODS: Overall, 889 miniscrews were successively inserted into 347 patients because some loosened or fell off once, twice, or more before achieving their purposes. The number of miniscrew failures (ie, once, twice, or more) was defined as progressive susceptibility to failure. The clinical indicators were assessed via univariate analysis, multicollinearity diagnosis, and Poisson log-linear regression model with stepwise calculation to screen out. RESULTS: The progressive susceptibility of miniscrews to failure was proved to be affected by the age of patients, the onset of force application, site of placement, and appliance type. Age and onset of force application presented a negative relationship with susceptibility. Miniscrews inserted in the palatal region appeared to be more stable than the forepart of the arch. In contrast, the retromaxillary and retromandibular areas obtained the lowest stability. The patients with fixed appliances were more unlikely to suffer progressive failure than removable appliances. In addition, the larger number of screws inserted in each patient, the greater probability of failure. CONCLUSIONS: Younger people with removable appliances that miniscrews inserted in the retromaxillary or retromandibular regions and earlier onsets of loading had a higher progressive susceptibility to loosening. Meanwhile, the failure rate was elevated with the increasing number of screws per patient received.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.