2022 Operative dentistry

Protective Barriers and Radiant Exposure Delivered from Light-curing Units.

, , , , , ,

Operative dentistry Vol. 47 (5) : E222-E232 • Sep 2022

OBJECTIVE: To evaluate the influence of different protective barriers as a function of the photoactivation distances on the radiant exposure of several light-curing units (LCU). The influence of the protective barriers on the degree of conversion of an adhesive resin was also evaluated. METHODS: Five LCUs were evaluated: Valo Cordless-used in standard mode (Ultradent, South Jordan, USA); Radii-cal-used in continuous mode (SDI, Bayswater, AU); Emitter D-used in continuous mode (Schuster, Santa Maria, BR); Bluephase N-used in high-intensity mode (Ivoclar Vivadent, Schaan, LI); and Rainbow Curing Light-used in continuous mode (Axdent, Guangdong, CN). For each LCU, radiant exposure was measured with a spectrometer (MARC Resin Calibrator) using three different protective barriers (low-density polyethylene, polyvinyl chloride, or Radii-cal barrier sleeves) and five photoactivation distances (0, 2, 5, 10, and 20 mm). The degree of conversion of an adhesive resin (Adper Scotchbond Multi-Purpose, 3M ESPE, St. Paul, USA) was measured through Fourier-transform infrared spectroscopy. The translucency parameter of protective barriers was measured with a spectrophotometer. For all statistical tests, a significance level of alpha = 0.05 was set. RESULTS: For all LCUs tested, radiant exposure was found to be significantly influenced by both protective barriers and curing distance (p</=0.001). In general terms, all the protective barriers significantly decreased the radiant exposure. Radii-cal barrier sleeves were the protective barrier that most decreased the radiant exposure. Irrespective of the protective barrier used, none of the LCU equipment reached the required minimum radiant exposure of 16 J/cm2 at 10 mm of curing distance. The degree of conversion was not effected by either LCU or a protective barrier (p>/=0.211). CONCLUSIONS: Protective barriers and photoactivation distance reduced the radiant exposure emitted by different LCUs.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.