The aims of this study were to evaluate the optical properties of flowable and injectable composites after polishing, such as translucency (translucency parameter [TP], TP(00)), opalescence (OP-BW), chroma (C*ab), refractive index (RI), and change in surface roughness (Ra, Rz). Ninety disc-shaped samples were prepared from micro-hybrid, flowable, and injectable composites and divided into 3 groups according to the polishing systems (n=10). The RI was measured with an Abbe refractometer, and optical measurements were performed with a spectrophotometer. The surface roughness was measured with a two-dimensional profilometer. Data were analyzed with the generalized linear model method and two-way analysis of variance. The results showed that the polishing procedure did not significantly impact the RI (p=0.987). Injectable composite had the highest translucency (TP=28.67; TP(00)=13.49) and opalescence (OP-BW=13.11); showed the lowest C*ab value (17.95). Also, the effects of the composite type and polishing procedure on surface roughness were statistically significant (p=0.047 and p<0.001).