OBJECTIVES: This study aimed to evaluate the release of calcium ions from a bioactive restorative material and its shear bond strength (SBS) to primary dentin. STUDY DESIGN: Occlusal surface of extracted non-carious primary molars were flattened, onto which 2 x 2 mm cylinders of ACTIVA BioActive Restorative (PULPDENT(R) Corporation, Watertown MA) or Fuji II LC (GC Corporation, Tokyo, Japan) were prepared using a polypropylene straw mould. SBS of the materials to primary dentin was tested using a universal testing machine. The mode of bond failure was assessed using stereomicroscopy. 10 mm x 2 mm disks of each material were prepared and immersed in Milli-Q water for 1, 7, 14 and 21 days. The released calcium ions in the immersion media were quantified using Atomic Absorption Spectroscopy. RESULTS: ACTIVA BioActive Restorative showed a mean SBS of 4.29 +/- 0.65 MPa to primary dentin and calcium ion release of 0.76 +/- 0.12 ppm over 21 days. CONCLUSION: ACTIVA BioActive Restorative showed a significantly higher mean SBS to primary dentin, and significantly higher calcium ion release compared to Fuji II LC.
No clinical trial protocols linked to this paper
Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.PICO Elements
No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.
Paper Details
MeSH Terms
Associated Data
No associated datasets or code repositories found for this paper.
Related Papers
Related paper suggestions will be available in future updates.