2023 Clinical oral investigations

Efficacy of upper-incisor torque control with clear aligners: a retrospective study using cone-beam computed tomography.

, , , , , ,

Clinical oral investigations Vol. 27 (7) : 3863-3873 • Jul 2023

OBJECTIVES: The objectives of this retrospective clinical study were to evaluate the efficacy of clear aligners on upper-incisor torque control, with the expectation of providing guidance for clinics. MATERIALS AND METHODS: Pretreatment (T0) and posttreatment (T1) cone-beam computed tomography (CBCT) scans of 47 patients with a nonextraction treatment using clear aligners were obtained and 120 upper-incisors with torque >/=5 degrees were selected. Voxel-based superimpositions were performed using Dolphin imaging software and achieved movements were then measured. Difference between achieved and predicted movement (DAPM) and the efficiency for upper-incisor torque were used to evaluate the torque control efficacy. RESULTS: The achieved torque movement with clear aligners was lower than predicted significantly, as the mean efficiency was 46.81+/-33.95%. Additionally, the achieved incisor movement of the crown and root differed significantly from the predicted movement, especially root movement. CONCLUSIONS: Clear aligners struggle to control upper-incisor torque, particularly root movement. In that case, overcorrection is necessary to prevent torque loss. CLINICAL RELEVANCE: Clear aligners remain a limitation on torque control and overcorrection should be considered.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.