2025 The Journal of prosthetic den…

Evaluation of accuracy of deep learning and conventional neural network algorithms in detection of dental implant type using intraoral radiographic images: A systematic review and meta-analysis.

, , , , , , ,

The Journal of prosthetic dentistry Vol. 133 (1) : 137-146 • Jan 2025

STATEMENT OF PROBLEM: With the growing importance of implant brand detection in clinical practice, the accuracy of machine learning algorithms in implant brand detection has become a subject of research interest. Recent studies have shown promising results for the use of machine learning in implant brand detection. However, despite these promising findings, a comprehensive evaluation of the accuracy of machine learning in implant brand detection is needed. PURPOSE: The purpose of this systematic review and meta-analysis was to assess the accuracy, sensitivity, and specificity of deep learning algorithms in implant brand detection using 2-dimensional images such as from periapical or panoramic radiographs. MATERIAL AND METHODS: Electronic searches were conducted in PubMed, Embase, Scopus, Scopus Secondary, and Web of Science databases. Studies that met the inclusion criteria were assessed for quality using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Meta-analyses were performed using the random-effects model to estimate the pooled performance measures and the 95% confidence intervals (CIs) using STATA v.17. RESULTS: Thirteen studies were selected for the systematic review, and 3 were used in the meta-analysis. The meta-analysis of the studies found that the overall accuracy of CNN algorithms in detecting dental implants in radiographic images was 95.63%, with a sensitivity of 94.55% and a specificity of 97.91%. The highest reported accuracy was 99.08% for CNN Multitask ResNet152 algorithm, and sensitivity and specificity were 100.00% and 98.70% respectively for the deep CNN (Neuro-T version 2.0.1) algorithm with the Straumann SLActive BLT implant brand. All studies had a low risk of bias. CONCLUSIONS: The highest accuracy and sensitivity were reported in studies using CNN Multitask ResNet152 and deep CNN (Neuro-T version 2.0.1) algorithms.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.