2024 The Journal of prosthetic den…

Bond strength of prefabricated and CAD-CAM milled glass fiber post-and-cores luted with conventional, universal, and self-adhesive composite resin cement.

, , , , ,

The Journal of prosthetic dentistry Vol. 131 (2) : 251.e1-251.e7 • Feb 2024

STATEMENT OF PROBLEM: Little is known about the effect of different composite resin cements on the bond strength of prefabricated and milled glass fiber post-and-cores. PURPOSE: The purpose of this in vitro study was to compare the push-out bond strengths of root dentin and standard, relined, or computer-aided design and computer-aided manufacturing (CAD-CAM) glass fiber post-and-cores luted with conventional, universal, or self-adhesive composite resin cement. MATERIAL AND METHODS: Post spaces were prepared in 90 premolars. Standard and relined prefabricated and CAD-CAM-milled glass fiber post-and-cores were luted with conventional (RelyX ARC; 3M ESPE), universal (RelyX Ultimate; 3M ESPE), and self-adhesive (RelyX U200; 3M ESPE) composite resin cement (n=10). All specimens were thermally aged (5000 cycles at 5 degrees C and 55 degrees C with a 20-second dwell time) and mechanical fatigue (1 000 000 cycles at 2 Hz, 50-N load). The specimens were sectioned perpendicularly to the root long axis into 1-mm-thick sections (apical, middle, and cervical root thirds), the push-out bond strength was determined, and the mode of failure recorded. Data were submitted to the Kruskal-Wallis test followed by the Bonferroni-Dunn multiple comparison test (alpha=.05). RESULTS: Push-out bond strength values did not differ (P>.05) among posts at the same root thirds. Standard posts showed higher bond strength than CAD-CAM at the apical third for data grouped by composite resin cements (P<.001). The cervical root thirds had higher bond strength than the apical thirds (P<.05). The cervical, middle, and apical root thirds showed decreasing bond strength values for each type of post for data grouped by composite resin cement (P<.001). Adhesive failures at the dentin-cement interface were predominant. CONCLUSIONS: The type of posts and cements did not affect the bond strength of glass fiber posts. The cervical root thirds had better bonding performance than the apical thirds.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.