2025 The International journal of …

Fracture Load Comparison of a New Fiber-Reinforced Composite and Zirconia in All-on-4 Prostheses: An In Vitro Study.

, , , , , , , , ,

The International journal of prosthodontics Vol. 38 (3) : 315-323 • May 2025

PURPOSE: To compare the fracture load of two framework materials-zirconia and a new fiber reinforced composite (FRC Trilor)-for full-arch, implant-supported rehabilitations using various cross-sections. MATERIALS AND METHODS: A cobalt-chromium metal model simulating the All-on 4 concept and including two anterior straight and two posterior 45-degree, multiunit digital implant analogs was manufactured. Four straight multiunit abutments were screwed onto the implant analogs. The metallic model was scanned, and 18 frameworks were fabricated, with 9 made of zirconia and 9 made of FRC Trilor. The frameworks were then divided into six groups (n = 3). Group division was based on the material type (zirconia or FRC Trilor) and framework cross-section: 3.5 x 6 mm2, 5.5 x 6 mm2, or 7.5 x 6 mm2. All specimens underwent thermocycling in two baths, were cemented to the abutments of the metal model, and were subjected to a load-to-failure bending test at three different points using a universal testing machine (crosshead speed: 1 mm/minute) until complete fracture occurred. Descriptive statistics were used to present quantitative variables as means +/- SDs. To compare two means, Student t test or Mann-Whitney test was used, and ANOVA test was used for three means. RESULTS: The FRC Trilor group with a 7.5 x 6 mm2 cross-section exhibited the highest load-to- failure values (ranging from 1,020 N to 2,994 N), while the zirconia group with a 3.5 x 6 mm2 cross-section recorded the lowest values (ranging from 212 N to 1,287 N). The material type and framework cross-section significantly affected the mean load-to-fracture values (P < .05). Regardless of the framework cross-section, the FRC Trilor group exhibited higher fracture loads than the zirconia group. In both materials, fracture load values increased with larger framework cross-sectional areas, with the highest values observed at the interimplant midpoint. CONCLUSIONS: FRC Trilor demonstrated a fracture load that makes it a suitable alternative to zirconia for All-on-4 implant prosthetic frameworks.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.