OBJECTIVES: This study evaluated the phase composition, phase transformation behaviour, and mechanical properties of five heat-treated NiTi instruments. METHODS: ProTaper NEXT (M-wire, PTN), ProTaper Gold (Gold-wire, PTG), One Curve (C-wire, OC), EdgeTaper Platinum (Fire-wire, ETP), NeoNiTi (electrical discharge machining-wire, NNA), and ProTaper Universal (conventional wire, PTU, control) with #25-tip size were tested (n = 12/group) for cyclic fatigue resistance (number of cycles to failure; NCF) and torsional resistance (angle of rotation to fracture and maximum torque at fracture [ultimate torsional strength]). The geometry and fracture surfaces of the tested instruments were examined by scanning electron microscopy. The phase transformation temperature and phase composition of the instruments were evaluated using differential scanning calorimetry and X-ray diffraction. Data were statistically analysed using one-way ANOVA and Tukey's post hoc test, with the significance level set at 5%. RESULTS: PTG showed the highest NCF (P < .05) at 37 degrees C, while ETP exhibited the highest angle of rotation to fracture, ultimate torsional strength, and stiffness (P < .05). Scanning electron microscopy demonstrated typical clusters of fatigue striations and numerous cracks after cyclic fatigue fracture, whereas there was a concentric abrasion pattern with a dimple and microvoids at the centre after torsional fracture. In differential scanning calorimetry curves, austenite-finishing temperatures of heat-treated instruments were higher than 37 degrees C, whereas that of PTU was lower than 37 degrees C. PTU showed strong peaks of austenite at 25 and 37 degrees C, whereas ETP showed a strong peak of R-phase at 25 degrees C, but mostly austenite phase at 37 degrees C in X-ray diffraction. CONCLUSIONS: Geometry, alloy type, and phase transformation temperatures of NiTi instruments affected their mechanical behaviour. CLINICAL RELEVANCE: PTG showed the highest NCF, suitable for markedly curved canals. ETP had the highest torsional resistance, appropriate for narrow and constricted canals.
No clinical trial protocols linked to this paper
Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.PICO Elements
No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.
Paper Details
MeSH Terms
Associated Data
No associated datasets or code repositories found for this paper.
Related Papers
Related paper suggestions will be available in future updates.