2025 Clinical implant dentistry an…

Long-Term Clinical and Radiographic Outcomes of Hydrophilic Implants: A 10-Year Study in a Specialist Private Practice.

, , , , , , , ,

Clinical implant dentistry and related research Vol. 27 (1) : e13415 • Feb 2025

AIM: To report the 10-year clinical and radiographic outcomes of implants placed in grafted (GBR) and non-grafted (no-GBR) sites in a Swiss specialist private practice using hydrophilic implants with a low surface roughness flange. METHODS: Fifty consecutively enrolled patients received 159 hydrophilic implants with a low surface roughness flange. A first re-evaluation was performed 1 year after delivery of restoration (T1). An additional examination was performed at the 10-year follow-up (T2) including the assessment of clinical (i.e., periodontal/peri-implant pockets probing depths (PPD) (mm), full-mouth bleeding score (%), implant survival rate, mid-buccal keratinized mucosa (KM) width in mm, and peri-implant phenotype), and radiographic (i.e., marginal bone level change [DeltaMBL]) outcomes. Biological, mechanical and technical complications were also recorded. RESULTS: Out of the initial cohort, 22 patients (9/40.9% male and 13/59% female) and 63 implants (47 with GBR, 16 without GBR), could be re-examined at T2. Overall, DeltaMBL (T2-T1) was -0.56 +/- 0.96 mm. In the GBR group, DeltaMBL were significantly higher at the distal sites compared to the no-GBR group (-0.75 +/- 1.17 mm vs. -0.12 +/- 1.29 mm, p = 0.045), however, in the GBR group MBL started at a higher level at T1 but were similar with the no-GBR group at T2. Implant survival was 100% with only very few technical complications (6.3%). Mean PPD amounted to 3.84 +/- 1.00 mm with significantly higher values in the GBR group (3.98 +/- 1.08 mm vs. 3.45 +/- 0.60 mm; p = 0.016). Nineteen implants (30.1%) were diagnosed with peri-implant health while 44 (69.9%) presented with peri-implant mucositis. CONCLUSION: Within the limitations of this study, favorable clinical and radiographic conditions were recorded around hydrophilic implants with a low surface roughness flange placed in pristine and augmented bone after 10 years in function.

No clinical trial protocols linked to this paper

Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.
PICO Elements

No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.

Paper Details
MeSH Terms
Associated Data

No associated datasets or code repositories found for this paper.

Related Papers

Related paper suggestions will be available in future updates.