BACKGROUND: To evaluate the impact of different polishing systems on surface roughness (SR), surface gloss (SG), and vickers microhardness (VMH) of flowable bulk-fill composites reinforced with zirconium oxide fillers. METHODS: Two flowable bulk-fill composites reinforced with zirconium oxide fillers (PALFIQUE BULK FLOW, Filtek Bulk Fill Flowable) and another one with conventional fillers (Tetric N-Flow Bulk Fill) were used. For each tested material, 40 cylindrical specimens (8-mm diameter, 4-mm height) were prepared. Specimens were divided into 4 subgroups according to polishing system used (n = 10/subgroup): subgroup I; Mylar strip (control), subgroup II; 1-step polishing system, subgroup III; 2-step polishing system, and subgroup IV; multi-step polishing system. Surface roughness was evaluated with a 3D noncontact optical profilometer. Gloss was evaluated with a glossmeter. Microhardness was evaluated with a Vickers Microhardness tester. Statistical analysis was performed using two-way ANOVA, Bonferroni, and Pearson correlation coefficient testes (p < 0.05). RESULTS: For surface roughness, there was no significant difference between groups for control and 1-step (p = 0.152 for control, p = 0.296 for 1-step), while there was a significant difference for 2-step and multi-step (p = 0.025 for 2-step, p = 0.001 for multi-step). For gloss, there was no significant difference between groups for 1-step and 2-step (p = 0.124 for 1-step, p = 0.226 for 2-step), while there was a significant difference for control and multi-step (p = 0.001 for control, p < 0.001 for multi-step). For microhardness, there was no significant difference between groups for control (p = 0.245), while there was a significant difference for the other techniques (p < 0.001 for 1-step and 2-step, p = 0.001 for multi-step). CONCLUSIONS: Reinforcement with zirconium oxide fillers improved flowable bulk-fill composites in terms of surface roughness, gloss, and microhardness. Surface gloss and microhardness were significantly influenced by material type and polishing system used, while surface roughness was influenced only by polishing system used.
No clinical trial protocols linked to this paper
Clinical trials are automatically linked when NCT numbers are found in the paper's title or abstract.PICO Elements
No PICO elements extracted yet. Click "Extract PICO" to analyze this paper.
Paper Details
MeSH Terms
Associated Data
No associated datasets or code repositories found for this paper.
Related Papers
Related paper suggestions will be available in future updates.